What are Haloacetic Acids?

Like trihalomethanes, haloacetic acids (HAAs) are a by-product of the chlorination of water which contains naturally-occurring dissolved organic matter. The five most common haloacetic acids are: monobromoacetic acid, dibromoacetic acid, monochloroacetic acid, dichloroacetic acid, and trichloroacetic acid. These compounds will also form when wastewater sources, such as sewage effluent, are disinfected.

Note that all of these halo (chlorine/bromine) compounds are some variation based on acetic acid, the impure form of which is vinegar. To understand the differences between these five compounds, first consider acetic acid whose formula could be written CH3– COOH. The –COOH end is the acid end but notice the other end, the CH3–. To make the five haloacetic acids, remove one or more of the hydrogens from the CH3– and replace them with chloride (the ion of the element, chlorine) or bromide (the ion of the element bromine). Remember that mono means one, di is two, and tri is three. If you replace one of those hydrogens with a bromide (bromo) you get monobromoacetic acid. With two bromides you get dibromoacetic acid. If you replace the hydrogens with one chloride (chloro), you get monochloroacetic acid while two and three chlorides result in dichloro- and trichloro-acetic acid, respectively.

How Do Haloacetic Acids Become a problem?

Haloacetic acids do not readily volatilize and they do not absorb very readily through the skin. Therefore, the primary route of exposure is via drinking and other forms of consumption. At high concentrations of haloacetic acids given to animals in studies, toxic effects have been identified in the liver, testes, pancreas, brain, cause development defects, low birth weight, and nervous system issues.

What are the Health Risks for Haloacetic Acids?

Based on animal and human studies, the US EPA considers two specific HAAs, i.e., dichloroacetic acid and trichloroacetic acid to be potential human carcinogens (bladder cancer) and, in animal studies, associated with liver cancer.

Disinfection by-products such as HAAs can form in water when disinfectants used to control microbial pathogens combine with naturally occurring materials found in source water. The National Primary Drinking Water Standards and related rules apply to all Community Water Systems and Non-Transient Non-Community Water Systems that add/deliver a primary or residual disinfectant, and Transient Non-Community Water Systems that use chlorine dioxide. This Rule does not apply to water systems that use ultraviolet (UV) light for disinfection. (Source)

What are the Standards for Haloacetic Acids?

The Stage 2 disinfection-products rule from the National Primary Drinking Water Standards expands the disinfection products to include HHAs. Haloacetic acids (monobromoacetic acid, dibromoacetic acid, monochloroacetic acid, dichloroacetic acid, and trichloroacetic acid) are byproducts of chlorination similar to trihalomethanes. From the 2018 edition of the Drinking Water and Health Advisory, the EPA has set a total limit for the five haloacetic acids of 0.06 mg/L.

For dichloroacetic acid, the MCL is 0.06 mg/L, but the MCLG is 0, the DWEL is 0.1 mg/L and the Life-time Limit is 0.03 mg/L.

For monochloroacetic acid, the MCL is 0.06 mg/L, but the MCLG is 0.07 mg/L, the DWEL is 0.35 mg/L, and the Life-time Limit is 0.07 mg/L.

For trichloroacetic acid, the MCL is 0.06 mg/L, but the MCLG is 0.02 mg/L, the DWEL is 1 mg/L, and the Life-time Limit is 0.02 mg/L.

Bromoacetic acid and dibromoacetic acid are regulated with this group but have no MCLGs. The primary concern related to excessive levels of HHAs is the potential adverse impact on the liver or nervous system.

Get Tested | Haloacetic Acids

You may be concerned about HHAs if you get your water from a city water source or a system that is a regulated non-transient non-community water system, such as a school, or if you have chlorinated water brought to your home as a source of potable water. Private water systems are not likely to have this problem unless you use a shallow well, a surface water source, or a rain collection system and use a strong oxidant like chlorine as a disinfectant.

Level 1 | Observational Self-Testing

Notes on Level 1 Testing for Haloacetic Acids

The only warning sign may be that the drinking water has either a strong chlorine smell or the water occasionally smells like diluted lake or pond water. The only other warning sign would be information that may be contained in the Consumer Confidence Report for your regulated drinking water source and intermittent discolored water with or without an odor and if the system has recently announced a boil water advisory.

Observations for Haloacetic Acids

If you have city water, you may have a problem with haloacetic acid, if:

  • The water has a strong chlorine odor
  • The original source of the water is from a surface water source, such as a lake, stream, or reservoir
  • You reviewed your Consumer Confidence Report and the water supplier has informed you of this condition


If you have well water, you may have a problem if you repeatedly treat your well by Shock Disinfection or treat the water using a chemical disinfectant.

Try Our Level 1 Drinking Water Self-Diagnostic Tool
Have water issues? Answer our self-diagnosis questionnaire from your observations to get an initial diagnosis. Then follow our recommended steps to remediate your issue.
Self-Diagnostic Tool

Level 2 | Do-It-Yourself Water Testing

Level 2 Testing is Do-It-Yourself testing that can be done in your own home using a Testing Kit. After you’ve done Level 1 Testing, Level 2 Testing can confirm if your observations are correct. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment (see below) or continue to Level 3 Testing.

Notes on Level 2 Testing for Haloacetic Acids

There is really no low-cost self-screening test or tool for chlorine by-products in drinking water, but there are dip tests and other meters that will permit you to monitor the total and free-chlorine residual of your water and other general water quality parameters.

Recommended Level 2 Tests
ST-CRYS-T-02
Crystal Quest
Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-T-02
Crystal Quest
Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

LT-CRYS-C-06
Crystal Quest
Commercial Multi-Media Water Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POE System)</div>

LT-FILT-S-01
Filter Water
Sediment Water Filter 10 Inch 5 Micron (Code A27AC)

<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>

ST-AMAZ-A-01
Amazon
AquaBliss High Output Revitalizing Shower Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: If the concentration of alpha is < 5 pCi/L - (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: If the concentration is < 4 millirems/year - (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: If the concentration of combined radium is < 5 pCi/L, alpha and beta are low, and radon less than 300 pCi/L - (POU Device)</div>

Recommended Products
Crystal QuestST-CRYS-T-02 | Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

View
Crystal QuestLT-CRYS-T-02 | Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

View
Crystal QuestLT-CRYS-C-06 | Commercial Multi-Media Water Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POE System)</div>

View
Filter WaterLT-FILT-S-01 Sediment Water Filter 10 Inch 5 Micron

<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>

View
AmazonST-AMAZ-A-01 | AquaBliss High Output Revitalizing Shower Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: If the concentration of alpha is < 5 pCi/L - (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: If the concentration is < 4 millirems/year - (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: If the concentration of combined radium is < 5 pCi/L, alpha and beta are low, and radon less than 300 pCi/L - (POU Device)</div>

View

Level 3 | Informational Water Testing

Level 3 Testing is done through an accredited Water Testing Laboratory. With Level 3 Testing, you can order a testing kit that is used to prepare your sample and submit it to the lab. By utilizing a lab, you have the assurance that a certified water expert had analyzed your water sample. If your test results reveal the presence of a contaminant that is cause for concern, you can either proceed to determine the best treatment options (see below) or continue to Level 4 Testing - Certified Testing.

Notes on Level 3 Testing for Haloacetic Acids

A number of informational water quality tests include chlorine and disinfection by-products. Typically these informational kits use the name or go by the term "City Water" testing kits, because most cities in the USA use chlorine to disinfect their drinking water. If you have well water and have never tested the well, we recommend conducting the City Water Check Deluxe. If you have had the well tested and are concerned about just Haloacetic Acids, then conduct the Tap Score testing.

Recommended Level 3 Tests
ST-CRYS-T-02
Crystal Quest
Triple Under-Sink Water Filter, 8-Stage

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-T-02
Crystal Quest
Thunder 2000M Reverse Osmosis System with Ultrafiltration

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

LT-CRYS-C-06
Crystal Quest
Commercial Multi-Media Water Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POE System)</div>

LT-FILT-S-01
Filter Water
Sediment Water Filter 10 Inch 5 Micron (Code A27AC)

<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>

ST-AMAZ-A-01
Amazon
AquaBliss High Output Revitalizing Shower Filter

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: If the concentration of alpha is < 5 pCi/L - (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: If the concentration is < 4 millirems/year - (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: If the concentration of combined radium is < 5 pCi/L, alpha and beta are low, and radon less than 300 pCi/L - (POU Device)</div>

Level 4 | Certified Water Testing

A Level 4 Certified Test Test uses chain-of-custody with a water professional coming to your home to prepare the water sample and then works with an accredited laboratory in order to certify your test results. This type of testing not only gives you the highest level of assurance in the accuracy of your test results, but can also be used as a document in legal cases. For Baseline Testing, we recommend that you use Certified Testing.

Notes on Level 4 Testing for Haloacetic Acids

If you are conducting certified testing for haloacetic acids, trihalomethanes, and chlorine by-products, it is also likely you are concerned about other aesthetic problems, nuisance bacteria, nuisance issues, and possibly even heterotrophic bacteria. If there are intermittent discolored water issues, you may also want to consider first-flush and flushed testing for trace metals associated with corrosion. If you need help or assistance with certified testing please Contact our team.

Get Treatment | Haloacetic Acids

It has been our experience that regulated water systems that have this problem include systems that primarily use a surface water source or a groundwater source that is vulnerable to nuisance bacteria or a system that has issues with managing the distribution system that results in dead-end legs, stagnant water, periods of very high or very low chlorine residuals, intermittent odors, and intermittent discolored water.

If you are a customer, your primary treatment option is the use of carbon filtration, but we DO NOT recommend the use of a "whole-house" Carbon Filtration system to remove all the residual chlorine from the water.  If you do remove all the residual chlorine, it is more likely you will have a potential for Bacterial regrowth in the distribution system.

Short Term Treatment

In the short-term, it may be necessary to work with the water company or authority to have them flush the water lines and consider the use of a point-of-use carbon filter on your drinking water.  If you have recently or need to Shock Disinfect the well, we recommend using the Well-Safe product.

Recommended Short-Term Water Treatments
ST-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

LT-CRYS-C-06
Crystal Quest

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POE System)</div>

LT-FILT-S-01
Filter Water

<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>

ST-AMAZ-A-01
Amazon

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: If the concentration of alpha is < 5 pCi/L - (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: If the concentration is < 4 millirems/year - (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: If the concentration of combined radium is < 5 pCi/L, alpha and beta are low, and radon less than 300 pCi/L - (POU Device)</div>

Long Term Treatment

The long-term solution can only be implemented by the water company or water authority. However, the consumer could consider installing a system to filter particles from the water, a Carbon Filtration system to remove some of the disinfection by-products, point-of-use or in-line carbon filters on drinking water faucets and shower heads and, in some cases, a Reverse Osmosis system on your primary drinking water tap.

Please note: We are not fans of a whole-house Carbon Filtration system that removes all the chlorine from your drinking water. We have found this approach ultimately leads to other problems within the distribution system because of Bacterial regrowth.

Recommended Long-Term Water Treatments
ST-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device) </div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration of trihalomethanes is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-mtbe-methyl-tert-butyl-ether">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device)</div>
<div class="product-note in-L6-toluene">Note: If the concentration is less than 0.8 mg/L</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1.0 mg/L (POU Device)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.07 mg/L (POU Device)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: Temporary Solution: If the concentration of alpha is < 5 pCi/L (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: Temporary Solution: If the concentration is < 4 millirems/year (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: Temporary Solution: If combined concentration is less than 5 pCi/L and alpha, beta, and uranium are below drinking water limit (POU Device)</div>
<div class="product-note in-L6-total-dissolved-solids">Note: Consider this treatment If the problem appears to be related to a metal or hardness.</div>

LT-CRYS-T-02
Crystal Quest

<div class="product-note in-L6-benzene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-carbon-tetrachloride">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chloroform-trichloromethane">Note: If the concentration is < 0.080 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-ethylbenzene">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-methylene-chloride-dichloromethane-dcm">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-tetrachloroethylene">Note: If the concentration is < 0.005 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trichloroethylene">Note: If the concentration is < 0.004 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-xylenes">Note: If the concentration is < 1 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-atrazine">Note: If the concentration is < 0.001 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-alachlor">Note: If the concentration is < 0.002 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-glyphosate">Note: If the concentration is < 0.7 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-2-4-d">Note: If the concentration is < 0.03 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-bis-2-ethylhexyl-phthalate">Note: If the concentration is < 0.006 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device System Component)</div>
<div class="product-note in-L6-chlorite">Note: If the concentration is < 0.8 mg/L (POU Device System Component)</div>

LT-CRYS-C-06
Crystal Quest

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POE System)</div>

LT-FILT-S-01
Filter Water

<div class="product-note in-L6-trihalomethanes">Note: The 10 inch sediment filter and housing will remove particles not Trihalomethanes, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>
<div class="product-note in-L6-haloacetic-acids">Note: The 10 inch sediment filter and housing will remove particles not Haloacetic Acids, but you can purchase the sediment filter housing and add a carbon block cartridge instead of the sediment cartridge. The carbon block cartridge is <a href="https://www.filterwater.com/p-117-10x5-carbon-block-cartridge.aspx?affid=10156" target="_blank" >FIlterWater part CQ-R5-10*5</a></div>

ST-AMAZ-A-01
Amazon

<div class="product-note in-L6-trihalomethanes">Note: If the concentration is < 0.08 mg/L (POU Device)</div>
<div class="product-note in-L6-haloacetic-acids">Note: If the concentration is < 0.06 mg/L (POU Device)</div>
<div class="product-note in-L6-gross-alpha">Note: If the concentration of alpha is < 5 pCi/L - (POU Device)</div>
<div class="product-note in-L6-beta-particles">Note: If the concentration is < 4 millirems/year - (POU Device)</div>
<div class="product-note in-L6-radium-226-and-radium-228">Note: If the concentration of combined radium is < 5 pCi/L, alpha and beta are low, and radon less than 300 pCi/L - (POU Device)</div>

If the concentration is at or over 0.060 mg/L - Recommendation: Seek Advice from a Local Professional (Customized Solution). Contact Us

Archive Page Reference
This is a newly redesigned Water-Research.net page. To reference related archived Water-Research.net page(s) click the link(s) below:
No items found.

in-L6-haloacetic-acids